DOORS
FIRE DOORS
Flora Ltd offers its customers production of a single wooden door with fire resistance of 60 minutes (EI60) and 45 minutes (EI45).
Due to the carefully-crafted 72 mm thick door profile with 2 rubber seals and 2 fire resistant self-expanding tapes for additional smoke insulation, they not only provide the desired fire resistance, but also successfully meet the highest sound insulation requirements (~43dB*).
Due to the integrated 3-point lock and easy-adjustable stainless steel hinges, these doors will serve as the entrance door for both hotel rooms and apartments.
To ensure maximum sealing of the door sash, a 40mm low solid wood threshold is integrated into the door. Fire doors are available painted (according to RAL or NCS catalogues) or veneered using quality A sliced oak or walnut veneer and stained in one of the 54 tones offered.
Fire doors are manufactured according to the certificate issued by BM TRADA Latvija Ltd.
Your Title Goes Here
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
Certificate
DO YOU HAVE ANY QUESTIONS?
WE WILL BE IN CONTACT WITHIN THE NEXT WORKING DAYS.
"*" indicates required fields
DO YOU HAVE ANY QUESTIONS?
WE WILL BE IN CONTACT WITHIN THE NEXT WORKING DAYS.
"*" indicates required fields
FIRE DOORS
Specification:
Your Title Goes Here
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
Dimensions of the certified door
980×2200 mm
Maximum door dimensions
+15% (horizontally or vertically), not exceeding + 20% of the total area of the doors tested
Dimensions of the door box
68×110 mm
Thickness of the door sash
72 mm
Threshold dimensions
110×40 mm solid wood threshold
Door material
Oak or walnut
Finishing
Painted or stained
Sealing
double sealing (+2 self-expanding tapes for smoke insulation)
Closing
KFV AS-2372 FS 3-point lock
Hinges
Standard (for EI60 doors) or concealed (for EI45 doors)
Handle
Application
Interior doors, entrance doors for apartments, entrance doors for hotel rooms
Possible additional equipment
A screw-on door closer